<emd xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" emdb_id="EMD-8538" version="3.0.0.0" xsi:schemaLocation="https://github.com/emdb-empiar/emdb-schemas/blob/master/v3/v3_0_0_0/emdb.xsd">
    <admin>
        <current_status>
            <date>2018-01-24</date>
            <code>REL</code>
            <processing_site>RCSB</processing_site>
        </current_status>
        <sites>
            <deposition>RCSB</deposition>
            <last_processing>RCSB</last_processing>
        </sites>
        <key_dates>
            <deposition>2016-12-22</deposition>
            <header_release>2017-02-01</header_release>
            <map_release>2018-01-24</map_release>
            <update>2018-01-24</update>
        </key_dates>
        <title>Structure of the p53/human RNA polymerase II assembly</title>
        <authors_list>
            <author>Liu WL</author>
            <author>Singh SK</author>
        </authors_list>
    </admin>
    <crossreferences>
        <citation_list>
            <primary_citation>
                <journal_citation published="true">
                    <author order="1">Singh SK</author>
                    <author order="2">Qiao Z</author>
                    <author order="3">Song L</author>
                    <author order="4">Jani V</author>
                    <author order="5">Rice W</author>
                    <author order="6">Eng E</author>
                    <author order="7">Coleman RA</author>
                    <author order="8">Liu WL</author>
                    <title>Structural visualization of the p53/RNA polymerase II assembly.</title>
                    <journal_abbreviation>Genes and Development</journal_abbreviation>
                    <volume>30</volume>
                    <first_page>2527</first_page>
                    <last_page>2537</last_page>
                    <year>2016</year>
                    <external_references type="PUBMED">27920087</external_references>
                    <external_references type="DOI">doi:10.1101/gad.285692.116</external_references>
                    <external_references type="ISSN">1549-5477</external_references>
                </journal_citation>
            </primary_citation>
        </citation_list>
        <emdb_list>
            <emdb_reference>
                <emdb_id>EMD-8538</emdb_id>
                <relationship>
                    <other>associated EM volume</other>
                </relationship>
            </emdb_reference>
        </emdb_list>
    </crossreferences>
    <sample>
        <name>Binary complex of p53 with human RNA polymerase II</name>
        <supramolecule_list>
            <complex_supramolecule supramolecule_id="1">
                <name>Binary complex of p53 with human RNA polymerase II</name>
                <parent>0</parent>
                <details>Assembly of native human RNA Polymerase II with human recombinant full-length p53</details>
                <natural_source database="NCBI">
                    <organism ncbi="9606">Homo sapiens</organism>
                    <strain>HeLa cells</strain>
                </natural_source>
                <molecular_weight>
                    <theoretical units="MDa">0.57</theoretical>
                </molecular_weight>
            </complex_supramolecule>
        </supramolecule_list>
    </sample>
    <structure_determination_list>
        <structure_determination structure_determination_id="1">
            <method>singleParticle</method>
            <aggregation_state>particle</aggregation_state>
            <specimen_preparation_list>
                <single_particle_preparation preparation_id="1">
                    <concentration units="mg/mL">0.026</concentration>
                    <buffer>
                        <ph>7.9</ph>
                        <component>
                            <concentration units="mM">20.0</concentration>
                            <formula>Hepes</formula>
                            <name>Hepes</name>
                        </component>
                        <component>
                            <concentration units="mM">0.2</concentration>
                            <formula>EDTA</formula>
                            <name>EDTA</name>
                        </component>
                        <component>
                            <concentration units="mM">2.0</concentration>
                            <formula>MgCl2</formula>
                            <name>MgCl2</name>
                        </component>
                        <component>
                            <concentration units="%">10.0</concentration>
                            <name>Glycerol</name>
                        </component>
                        <component>
                            <concentration units="mM">100.0</concentration>
                            <formula>KCl</formula>
                            <name>Potassium chloride</name>
                        </component>
                        <details>plus 0.05% NP40, 1 mM DTT and 0.5 mM PMSF</details>
                    </buffer>
                    <grid>
                        <model>Protochips CF-1.2/1.3-4C</model>
                        <mesh>400</mesh>
                        <support_film film_type_id="1">
                            <film_material>CARBON</film_material>
                            <film_topology>HOLEY</film_topology>
                        </support_film>
                        <pretreatment>
                            <type>GLOW DISCHARGE</type>
                        </pretreatment>
                        <details>A thin carbon film supported by a 400-mesh carbon-thickened C-flat holey grid with hole diameter 1.2 micron/spacing 1.3 micron (CF-1.2/1.3-4C, Protochips) was freshly glow discharged using a high-vacuum evaporator (Denton).</details>
                    </grid>
                    <vitrification>
                        <cryogen_name>ETHANE</cryogen_name>
                        <chamber_humidity units="percentage">100</chamber_humidity>
                        <chamber_temperature units="K">278.65</chamber_temperature>
                        <instrument>FEI VITROBOT MARK III</instrument>
                        <details>The assembled p53/Pol II co-complex was applied directly on the grid for 10 seconds followed by 5.5 seconds of blotting. The sample grid was then washed with 3.5 % Trehalose in 0.1 M KCl/HEM buffer (20 mM HEPES, 0.2 mM EDTA, 2 mM MgCl2, pH 7.9) for 10 seconds, blotted for 5.5 seconds and finally plunged frozen in liquid ethane.. </details>
                    </vitrification>
                </single_particle_preparation>
            </specimen_preparation_list>
            <microscopy_list>
                <single_particle_microscopy microscopy_id="1">
                    <microscope>FEI TITAN KRIOS</microscope>
                    <illumination_mode>FLOOD BEAM</illumination_mode>
                    <imaging_mode>BRIGHT FIELD</imaging_mode>
                    <electron_source>FIELD EMISSION GUN</electron_source>
                    <acceleration_voltage units="kV">300</acceleration_voltage>
                    <nominal_cs units="mm">2.7</nominal_cs>
                    <nominal_defocus_min units="&#181;m">0.5</nominal_defocus_min>
                    <nominal_defocus_max units="&#181;m">3.0</nominal_defocus_max>
                    <nominal_magnification>22500.</nominal_magnification>
                    <specimen_holder_model>FEI TITAN KRIOS AUTOGRID HOLDER</specimen_holder_model>
                    <cooling_holder_cryogen>NITROGEN</cooling_holder_cryogen>
                    <image_recording_list>
                        <image_recording image_recording_id="1">
                            <film_or_detector_model>GATAN K2 SUMMIT (4k x 4k)</film_or_detector_model>
                            <detector_mode>COUNTING</detector_mode>
                            <digitization_details />
                            <average_electron_dose_per_image units="e/&#8491;^2">66.8</average_electron_dose_per_image>
                        </image_recording>
                    </image_recording_list>
                </single_particle_microscopy>
            </microscopy_list>
            <singleparticle_processing image_processing_id="1">
                <image_recording_id>1</image_recording_id>
                <ctf_correction>
                    <software_list>
                        <software>
                            <name>CTFIND3</name>
                        </software>
                    </software_list>
                </ctf_correction>
                <startup_model type_of_model="RANDOM CONICAL TILT">
                    <random_conical_tilt>
                        <number_images>270</number_images>
                        <tilt_angle units="degrees">50</tilt_angle>
                    </random_conical_tilt>
                </startup_model>
                <final_reconstruction>
                    <number_classes_used>2</number_classes_used>
                    <applied_symmetry>
                        <point_group>C1</point_group>
                    </applied_symmetry>
                    <resolution res_type="BY AUTHOR" units="&#8491;">10.8</resolution>
                    <resolution_method>FSC 0.143 CUT-OFF</resolution_method>
                    <software_list>
                        <software>
                            <name>RELION</name>
                            <version>1.4</version>
                        </software>
                    </software_list>
                    <number_images_used>8097</number_images_used>
                </final_reconstruction>
                <initial_angle_assignment>
                    <type>PROJECTION MATCHING</type>
                    <projection_matching_processing />
                    <software_list>
                        <software>
                            <name>RELION</name>
                            <version>1.4</version>
                        </software>
                    </software_list>
                </initial_angle_assignment>
                <final_angle_assignment>
                    <type>PROJECTION MATCHING</type>
                    <projection_matching_processing />
                    <software_list>
                        <software>
                            <name>RELION</name>
                            <version>1.4</version>
                        </software>
                    </software_list>
                </final_angle_assignment>
                <final_three_d_classification>
                    <number_classes>2</number_classes>
                    <software_list>
                        <software>
                            <name>RELION</name>
                            <version>1.4</version>
                        </software>
                    </software_list>
                </final_three_d_classification>
            </singleparticle_processing>
        </structure_determination>
    </structure_determination_list>
    <map format="CCP4" size_kbytes="108001">
        <file>emd_8538.map.gz</file>
        <symmetry>
            <space_group>1</space_group>
        </symmetry>
        <data_type>IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)</data_type>
        <dimensions>
            <col>300</col>
            <row>300</row>
            <sec>300</sec>
        </dimensions>
        <origin>
            <col>0</col>
            <row>0</row>
            <sec>0</sec>
        </origin>
        <spacing>
            <x>300</x>
            <y>300</y>
            <z>300</z>
        </spacing>
        <cell>
            <a units="&#8491;">330.0</a>
            <b units="&#8491;">330.0</b>
            <c units="&#8491;">330.0</c>
            <alpha units="deg">90.0</alpha>
            <beta units="deg">90.0</beta>
            <gamma units="deg">90.0</gamma>
        </cell>
        <axis_order>
            <fast>X</fast>
            <medium>Y</medium>
            <slow>Z</slow>
        </axis_order>
        <statistics>
            <minimum>-0.0074459417</minimum>
            <maximum>0.018558849</maximum>
            <average>0.00033213312</average>
            <std>0.0015836135</std>
        </statistics>
        <pixel_spacing>
            <x units="&#8491;">1.1</x>
            <y units="&#8491;">1.1</y>
            <z units="&#8491;">1.1</z>
        </pixel_spacing>
        <contour_list>
            <contour primary="true">
                <level>0.0075</level>
                <source>AUTHOR</source>
            </contour>
        </contour_list>
        <label>::::EMDATABANK.org::::D_1000225352::::</label>
        <annotation_details>The cryo-EM 3D reconstruction of p53-bound human RNA Polymerase II</annotation_details>
    </map>
</emd>